In HVDC/AC interconnected system, commutation failure caused by AC system faults at the inverter side will adversely bring complicated transient characteristics about AC system, which has an influence on existing protection. This paper analyzes the adaptation of phase selector based on fault component in HVDC/AC system. Firstly, three phase switching function of commutation bridge is discussed, which is affected by both AC fault time and commutation failure times in a cycle after fault. Then, a precise method to calculate the post fault DC current based on control strategy is provided. On this basis, transient characteristics of inverter-side AC current and its influence on phase selector based on fault component is analyzed. It shows that commutation failure changes the switching function and generates current changes in non-fault phase, which may lead to malfunction of phase selector. Finally, PSCAD/EMTDC simulations are provided to verify the correctness of theoretical analysis.
机译:在HVDC / AC互连系统中,逆变器侧由于AC系统故障而导致的换向故障将给AC系统带来复杂的瞬态特性,从而影响现有保护。本文分析了基于故障分量的HVDC / AC系统中选相器的适应性。首先讨论了换相桥的三相切换功能,该功能受故障后交流故障时间和换相失败时间的影响。然后,提出了一种基于控制策略的故障后直流电流的精确计算方法。在此基础上,分析了逆变器侧交流电流的暂态特性及其对基于故障分量的选相器的影响。结果表明,换相失败会改变开关功能,并在非故障相中产生电流变化,这可能会导致选相器故障。最后,提供PSCAD / EMTDC仿真以验证理论分析的正确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号