首页> 外文会议>Annual Water Environment Federation technical exhibition and conference >Actual State of Main Pump Rotation Speed Control in Sewage Treatment Plants and Energy-saving Measures
【24h】

Actual State of Main Pump Rotation Speed Control in Sewage Treatment Plants and Energy-saving Measures

机译:污水处理厂主泵转速控制的现状及节能措施

获取原文

摘要

In the recent years, the rotation speed control of the main pump using an inverter (VVVF) has been increasing for energy saving purposes. On the other hand, there are cases where power consumption increases due to excessive rotation speed control ignoring pump characteristics. In the present study, we examined the change of operating method based on the power consumption analysis on two sewage treatment plants (located in City A and City B). In this analysis, the operation daily report data of the sewage plant is used, therefore, it can be applied to many sewage treatment plants. The simulation results with minimum rotation speed control showed that the reduction in power consumption is about 10% in city A and about 25% in city B. Especially, we could get about 21% reduction in City B, where the operation method was changed at the site based on the calculation conditions.
机译:近年来,出于节能的目的,使用逆变器(VVVF)的主泵的转速控制一直在增加。另一方面,存在由于过度的转速控制而忽略泵的特性而导致功耗增加的情况。在本研究中,我们基于对两个污水处理厂(分别位于A市和B市)的能耗分析,研究了运行方法的变化。在此分析中,由于使用了污水处理厂的运行日报数据,因此可以将其应用于许多污水处理厂。在最小转速控制下的仿真结果表明,A市的能耗降低了约10%,B市的能耗降低了约25%。特别是,B市的能耗降低了21%,其中改变了运行方式基于计算条件的站点。