The connection strength and stiffness sensitivity of screwed sidelaps in nestable steel decks to screw installation details has been experimentally explored via cyclic testing. The cyclic behavior of sidelaps has been recently incorporated in the high fidelity modeling and seismic evaluation of the steel deck diaphragm in rigid wall - flexible diaphragm buildings, where "unzipping" a sidelap (loss of a significant number of sidelap connections along a deck edge) could significantly reduce the seismic performance of the whole diaphragm. A total of 24 monotonic and cyclic sidelap tests have been performed in the Thin-Walled Structures Laboratory at Johns Hopkins University. Two different screw edge distances, three different deck thicknesses (i.e. 18 gauge 20 gauge, and 22 gauge), and two different screw sizes were included in the test matrix. The screws were installed either "close to the edge" or "far from the edge". For the "close to the edge" condition the typical 1.5d edge distance limitation in the design specification was not satisfied. Both monotonic and cyclic test results show that the strength of the sidelap connection can be correlated to edge distance and screw installation details. A maximum 25% and 19% difference in the ultimate strength of the screw sidelaps were observed in monotonic and cyclic tests, respectively. The rest results were compared to sidelap strengths in the literature, and potential changes to sidelap strength predictions and installation methods are discussed.
机译:通过循环测试实验性地探索了可嵌套钢甲板中的螺纹侧盖对螺钉安装细节的连接强度和刚度敏感性。侧板的循环特性最近已纳入刚性壁板-柔性膜结构建筑物中钢甲板隔板的高保真度建模和地震评估中,在该结构中,侧板“解压”(沿甲板边缘的大量侧板连接丢失)会大大降低整个膜片的抗震性能。在约翰·霍普金斯大学的薄壁结构实验室中,总共进行了24个单调和循环的搭接测试。测试矩阵中包括两种不同的螺钉边缘距离,三种不同的平台厚度(即18号规格20号规格和22号规格)以及两种不同的螺钉尺寸。螺钉“靠近边缘”或“远离边缘”安装。对于“接近边缘”条件,不满足设计规范中典型的1.5d边缘距离限制。单调和循环测试结果均表明,搭接连接的强度可以与边缘距离和螺钉安装细节相关。在单调测试和循环测试中,分别观察到了螺钉侧搭圈的极限强度最大差异为25%和19%。将其余结果与文献中的侧边强度进行了比较,并讨论了侧边强度预测和安装方法的潜在变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号