Distribution System Operators (DSO's) in the Netherlands are generally more focused on Medium Voltage (MV) grids than on Low Voltage (LV) grids as higher voltage levels contribute more to the SAIDI. However increasing interruption times, increasing costs and the energy transition on LV level encourage the DSO's to focus on LV grids as well. A first step is the investigation of failures in LV grid components. In this paper a literature review on this topic is presented and the outcomes are discussed. It is concluded that the method of modelling of ageing components on MV level cannot be applied to LV level because of the absence of temperature-related and electric stresses in LV components. In addition the possibilities for diagnostics are limited due to attenuation of electric signals. Although statistical methods are currently used for condition assessment of distribution grids, the LV level remains partly unspoilt terrain. However there remain some challenges related to data availability and quality. The use of statistical methods is investigated in further research in order to be able to perform condition assessment on LV level.
机译:荷兰的配电系统运营商(DSO)通常将重点放在中压(MV)电网上,而不是在低压(LV)电网上,因为更高的电压水平对SAIDI的贡献更大。但是,中断时间的增加,成本的增加以及低压水平的能量转换都促使DSO也将重点放在低压电网上。第一步是调查低压电网组件的故障。在本文中,对该主题进行了文献综述并讨论了结果。结论是,由于LV组件中不存在温度相关和电应力,因此在MV级别上建模老化组件的方法无法应用于LV级别。另外,由于电信号的衰减,诊断的可能性受到限制。尽管目前使用统计方法来评估配电网的状态,但低压水平仍然部分未被破坏。但是,仍然存在一些与数据可用性和质量有关的挑战。为了能够在LV水平上进行病情评估,在进一步的研究中对统计方法的使用进行了研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号