首页> 外文会议>International Universities Power Engineering Conference >Insulators' pollution problem: Experience from the coastal transmission system of Crete
【24h】

Insulators' pollution problem: Experience from the coastal transmission system of Crete

机译:绝缘子的污染问题:克里特岛沿海输电系统的经验

获取原文

摘要

Pollution of insulators is one of the most significant problems that can affect the reliability of power systems. Several practices have been employed to improve the insulation performance under polluted conditions such as extending the creepage distance, using specially designed profiles, washing of insulators and using hydrophobic materials to manufacture insulators or to coat their surfaces. Depending on the pollution type and severity as well as the local climatic conditions at the site of installation, different maintenance procedures against pollution should be employed. In this study, the insulators' pollution problem in the transmission system of Crete is described based on a statistical analysis of the insulators' faults since 1969. Also, the practices employed against insulators' pollution as well as their effectiveness are presented. Among them, the most efficient practice has been evinced the use of polymeric coatings and composite insulators. However, after about 2 decades of their large scale installation, without any faults, their performance becomes questionable due to the ageing of the polymeric materials. In order to prevent the risk of the in-service insulators failures, a fruitful collaboration of power network operator with local academia and research institutes has led to the investigation of new diagnostic procedures aiming at the assessment of the condition of field-aged insulators. To this end, the use of laser-induced breakdown spectroscopy (LIBS) technique is proposed for the remote and real-time diagnosis of the condition of in-service composite insulators.
机译:绝缘子的污染是可能影响电力系统可靠性的最重要问题之一。已经采取了多种措施来改善在污染条件下的绝缘性能,例如延长爬电距离,使用专门设计的轮廓,清洗绝缘子以及使用疏水性材料来制造绝缘子或对其表面进行涂层。根据污染类型和严重程度以及安装现场的当地气候条件,应采用不同的污染维护程序。在这项研究中,基于对自1969年以来绝缘子故障的统计分析,描述了克里特岛输电系统中的绝缘子污染问题。此外,还介绍了针对绝缘子污染的措施及其有效性。其中,最有效的做法是使用聚合物涂料和复合绝缘子。但是,在大规模安装大约20年之后,没有任何故障,由于聚合物材料的老化,其性能变得可疑。为了防止使用中的绝缘子发生故障的风险,电网运营商与当地学术界和研究机构的卓有成效的合作导致了针对旨在评估现场老化绝缘子状况的新诊断程序的研究。为此,提出了使用激光诱导击穿光谱技术(LIBS)技术对在役复合绝缘子状况进行远程和实时诊断的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号