Investigations on the make-welding behavior of high power contactors for AC and DC applications up to 3kV

机译:大功率接触器在高达3kV的AC和DC应用中的焊接性能研究

获取原文

摘要

Contrary to other test setups, a virtually unmodified contactor actuator has been integrated into a model switch to reproduce contact bouncing of make operations. This allows for a less complex machine than an electro mechanical or pneumatic replica of the original actuator. Furthermore optical and mechanical access to the contacts is significantly improved compared to a standard contactor. Scattered failure of the contact system has been traced down to contact welding during make operations instead of welding by over-currents in the on-state. Investigations of the welded contact have been rather limited without completely destroying the contactor housing for extraction. The model setup facilitates series switching with recording of electrical parameters as well as contact closing and separation forces and contact bridge displacement. Welded contacts can be teared open by an additional actuator to detect welding forces in place or can be simply disassembled for further analysis without damaging the weld spot. The authors present first results from their test sequences and reveal the significance of pre-impact arcing for the total energy dissipation in make operations.
机译:与其他测试设置相反,实际上未修改的接触器执行器已集成到模型开关中,以重现闭合操作的触点弹跳。与原始致动器的机电或气动复制品相比,这使机器的复杂程度降低了。此外,与标准接触器相比,触头的光学和机械通道得到显着改善。接触系统的零散故障可以追溯到制造操作期间的接触焊接,而不是导通状态下的过电流焊接。在不完全破坏接触器壳体以便抽出的情况下,对焊接接触器的研究相当有限。该模型设置通过记录电气参数以及触点闭合和分离力以及触点桥位移来促进串联切换。可以通过一个附加的执行器将焊接的触点拆开,以检测到适当的焊接力,或者可以简单地将其拆下以进行进一步分析,而不会损坏焊接点。作者从他们的测试序列中得出了第一批结果,并揭示了预冲击电弧对于制造过程中总能量耗散的重要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号