首页> 外文会议>International conference on nuclear engineering >THE SENSITIVITY OF THE ADDITION OF LOW-LOW PRESSURIZER PRESSURE IN COINCIDENCE WITH HIGH CONTAINMENT PRESSURE ON M310 TYPE NUCLEAR POWER PLANT
【24h】

THE SENSITIVITY OF THE ADDITION OF LOW-LOW PRESSURIZER PRESSURE IN COINCIDENCE WITH HIGH CONTAINMENT PRESSURE ON M310 TYPE NUCLEAR POWER PLANT

机译:M310型核电站的高低压重合低低压增压器的灵敏度

获取原文

摘要

Due to the new security system that the operator intervention is assumed to occur in 20 minutes is not acceptable, for the current M310 type nuclear power plant. The loss of coolant accident with Intermediate breaks in primary loop is the only one of design basis accident which need operator action in 20 minutes. For certain size break , the consequences are very sensitive to the pump stop time. According to deterministic analysis that for a certain size break, if stop the pump in 20 minutes after accident, the peak cladding temperature will exceed the limit value of 1204°C.Therefore, it is necessary to add low-low pressurizer pressure in coincidence with high containment pressure signal to stop pump automatically on M310 type nuclear power plant.
机译:由于新的安全系统,对于当前的M310型核电站,假定操作员干预发生在20分钟之内是不可接受的。一次回路中途发生中间中断而造成的冷却液损失事故是仅有的一种设计基准事故,需要操作员在20分钟内采取行动。对于一定的尺寸中断,后果对泵停止时间非常敏感。根据确定性分析,对于一定的尺寸中断,如果在事故发生后20分钟内停止泵运行,则最高包层温度将超过1204°C的极限值,因此有必要在适当的时候增加低低压增压器压力M310型核电站上的高安全壳压力信号自动停止泵。