This paper presents development of a device to detect knee sound signals for distinguish between normal subjects, patients with osteoarthritis before surgery and patients with osteoarthritis after surgery. Knee sound signals generated by knee movement so it difference in normal knee joint and degeneration of the knee joint surface. We detected the acoustical parameters, such as the fundamental frequency (F0), the mean amplitude of the pitches, the efficiency of F0 and the efficiency of A0. We compared them with three groups. We record knee sound from 36 normal subjects, 5 patients with osteoarthritis before surgery and 3 patients after surgery in two positions (sitting and standing). The mean values of F0 and A0 of the normal group were larger than other group. These result shows good potential for early detection between normal subject and patients with osteoarthritis before surgery and after surgery.
机译:本文提出了一种检测膝盖声音信号的装置,以区分正常受试者,手术前患有骨关节炎的患者和手术后患有骨关节炎的患者。膝盖运动产生的膝盖声音信号在正常的膝关节和膝关节表面的退化中会有所不同。我们检测了声学参数,例如基频(F0),音高的平均幅度,F0的效率和A0的效率。我们将它们与三组进行了比较。我们记录了36位正常受试者,5例手术前的骨关节炎患者和3例手术后的两个位置(坐姿和站立姿)的患者的膝盖声音。正常组的F0和A0平均值大于其他组。这些结果显示了在正常受试者与手术前后的骨关节炎患者之间进行早期检测的良好潜力。