Widespread deployment of Voltage Source Inverters (VSI-s) in high penetration applications like distributed generation, UPS and stand-alone renewable energy conditioning imposes stringent demands on reliability and output voltage regulation. Reported literature offers numerous solutions for output voltage regulation, which includes twin aspects of command tracking and output impedance control. Most of these methods rely on measurement of at least two separate variables per phase, which compromises overall reliability. This paper focuses on output voltage regulation approaches requiring measurement of a single variable, per phase. It is analytically shown that single-loop approaches are inadequate for satisfying both reference tracking and output impedance specifications. Subsequently, two new improvements using a multi-loop approach are proposed and performance of these techniques are predicted analytically. Experimental results are presented to confirm the validity of suggested approaches.
机译:电压源逆变器(VSI-s)在诸如分布式发电,UPS和独立可再生能源调节之类的高渗透性应用中的广泛部署对可靠性和输出电压调节提出了严格的要求。报道的文献为输出电压调节提供了许多解决方案,其中包括命令跟踪和输出阻抗控制的两个方面。这些方法大多数都依赖于每个阶段至少两个独立变量的测量,这会损害整体可靠性。本文着重于要求每相测量单个变量的输出电压调节方法。分析表明,单回路方法不足以满足参考跟踪和输出阻抗规范。随后,提出了使用多回路方法的两项新改进,并通过分析预测了这些技术的性能。提出实验结果以确认所建议方法的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号