首页> 外文会议>IEEE Industry Applications Society Annual Meeting >Pilot plant tests of a corona discharge-electron beam hybrid combustion flue gas cleaning system
【24h】

Pilot plant tests of a corona discharge-electron beam hybrid combustion flue gas cleaning system

机译:电晕放电 - 电子束混合燃烧烟气清洁系统的试验厂试验

获取原文

摘要

Pilot plant tests of a corona discharge-electron beam hybrid combustion flow gas cleaning system have been conducted. Gas flow rate of the test loop is a heavy oil fired boiler flue gas with 1200 m/sup 3/N/h, and one electron beam generator (500 kV/spl times/30 mA) is used with a corona discharge ammonia radical injection system (60 kV/spl times/5 mA). SO/sub 2/, CO, CO/sub 2/, NH/sub 3/, NO, NO/sub x/ and O/sub 2/ gases are monitored. The results show that up to 85% of NO/sub x/ and 98% of SO/sub x/ in flue gases are removed under a corona discharge-electron beam hybrid operations with significant small amount of leaked ammonias.
机译:已经进行了电晕放电 - 电子束混合燃烧流量气体清洁系统的试验厂试验。试验回路的气流速率是一种重油燃烧锅炉烟道气,具有1200米/升3 / n / h,一个电子束发电机(500 kV / spl时/ 30 mA)配合使用电晕放电氨基灭弧系统(60 kV / spl时间/ 5 mA)。所以/ SUB 2 /,CO,CO / SUB 2 /,NH / SUB 3 /,NO,NO / SUB X /和O / SUP 2 /气体被监测。结果表明,在电晕放电 - 电子束混合动力操作下,在具有显着少量泄漏的氨基次的电晕放电 - 电子束混合动态操作下除去高达85%的NO / SUB X /和98%的烟气。