In order to solve the problem of over temperature tube-burst caused by oxide scale shedding and blocking tubes of high temperature reheater of a 200MW super high pressure power plant boiler, this paper expounds the mechanism of scale forming and shedding, and analyzes the probable causes of the tube-burst failure. The results show that the root cause of scale forming is that greater steam extraction flow after reforming of the second extraction leads to less steam flow into reheater, which causes over temperature to some of the heated tubes; and the root cause of scale shedding is that long term operation in AGC-R mode brings about great fluctuations of unit load, steam temperature and pressure, accelerating scale shedding. In conclusion, preventive measures are drawn up considering the operation mode of the unit.
机译:为了解决200MW超高压电站锅炉高温再热器高温氧化炉氧化皮脱落和堵塞引起的过热管爆裂的问题,阐述了氧化皮形成和脱落的机理,并分析了可能的原因。爆裂失败的原因。结果表明,水垢形成的根本原因是在二次抽提重整后,较大的抽汽量导致较少的蒸汽流入再热器,从而导致某些加热管过热。结垢的根本原因是在AGC-R模式下长期运行会引起单位负载,蒸汽温度和压力的巨大波动,从而加速结垢。总之,应考虑设备的运行模式制定预防措施。