首页> 外文会议>Electrical Insulation Conference >Dielectric design validation of a helium gas cooled superconducting DC power cable
【24h】

Dielectric design validation of a helium gas cooled superconducting DC power cable

机译:氦气冷却超导直流电力电缆的介电设计验证

获取原文

摘要

Successful validation of the dielectric design of high temperature superconducting DC cables cooled with pressurized helium gas circulation is reported. The dielectric design features were developed based on the tests of several short sample cables. The features were adapted for the dielectric design of the cable and termination components such as high voltage bushings. A high voltage DC withstand test followed by AC partial discharge measurements on a 30-m long superconducting DC cable cooled with helium gas operating at 50–60 K showed that the dielectric design is suitable for the cable system.
机译:据报道,用加压氦气循环冷却的高温超导直流电缆的介电设计已得到成功验证。介电设计功能是根据对几条短采样电缆的测试而开发的。这些功能适用于电缆和端接组件(例如高压套管)的介电设计。在30m长的超导直流电缆上进行高压直流耐压测试,然后进行交流局部放电测量,该电缆使用氦气在50-60 K下冷却,这表明电介质设计适用于电缆系统。