首页> 外文会议>Annual IEEE Applied Power Electronics Conference and Exposition >Comparison of audible noise caused by magnetic components in switch-mode power supplies operating in burst mode and frequency-foldback mode
【24h】

Comparison of audible noise caused by magnetic components in switch-mode power supplies operating in burst mode and frequency-foldback mode

机译:在突发模式和频率折返模式下工作的开关电源中由磁性元件引起的可听噪声的比较

获取原文

摘要

In this paper, it is shown that operation of switch-mode power supplies in burst mode (BM) results in lower audible noise than operation in frequency-foldback mode (FFM). However, the selection of the switching frequency in a burst package can have a significant impact on the audible noise. In both BM and FFM, the audible noise can be reduced by decreasing the peak value of current pulses and proportionally increasing the burst frequency in BM and the switching frequency in FFM. In BM, the audible noise can be further reduced if instead of increasing the burst frequency, the number of burst pulses is increased without changing the burst frequency. The presented BM and FFM audible noise analysis is experimentally verified on a dc-dc boost test circuit.
机译:在本文中,可以证明,与突发频率折返模式(FFM)相比,突发模式(BM)的开关模式电源操作产生的可闻噪声更低。但是,在突发包中选择开关频率可能会对可听噪声产生重大影响。在BM和FFM中,都可以通过减小电流脉冲的峰值并按比例增加BM中的猝发频率和FFM中的开关频率来降低​​可听噪声。在BM中,如果在不更改突发频率的情况下增加突发脉冲的数量而不是增加突发频率,则可以进一步降低可听噪声。所提出的BM和FFM可听噪声分析已在dc-dc升压测试电路上进行了实验验证。