首页> 外文会议>World conference on timber engineering >RECOMMENDATIONS FOR DESIGN OF ANCHORING DEVICES FOR BOTTOM RAILS IN PARTIALLY ANCHORED TIMBER FRAME SHEAR WALLS
【24h】

RECOMMENDATIONS FOR DESIGN OF ANCHORING DEVICES FOR BOTTOM RAILS IN PARTIALLY ANCHORED TIMBER FRAME SHEAR WALLS

机译:关于部分锚固的木框架剪力墙底轨锚固装置设计的建议

获取原文

摘要

The authors have developed a new plastic design method for light-frame timber shear walls. The method is capable of analyzing the load-bearing capacity of partially anchored shear walls. For proper application of the plastic method it is necessary to ensure ductile behaviour of the sheathing-to-framing joints and to avoid brittle failure of the bottom rail in particular. In a partially anchored shear wall the leading stud is not fully anchored against uplift and corresponding tying down forces are developed in the sheathing-to-framing joints along the bottom rail in the sheathing segments close to the leading stud. These tying down forces in the joints may introduce a number of possible brittle failure modes or serviceability problems for the bottom rail that need to be eliminated or restricted in order for the plastic method to be applicable. This paper describes experimental results for proper design of washers or bearing plates for the anchor bolts in order to avoid splitting failure of and excessive washer indentation into the bottom rail. Specimens with both double and single sided sheathing and different locations of anchor bolts are studied. With respect to splitting of the bottom rail, the tests indicate that the failure load depends on the distance from the edge of the washer to the loaded edge of the bottom rail. With respect to large deformations due to bearing stresses of the washers of the anchoring bolts, the size of the washer is the most important parameter. The test results indicate that the bearing strength for large washers is lower than that proposed by Eurocode 5. In this paper, it is therefore proposed to make the bearing strength inverse proportional to the diameter or side length of the washer. Then, good agreement with the test results was found. The results show that failure due to splitting is the determining design mode.
机译:作者开发了一种用于轻型框架木剪力墙的新型塑料设计方法。该方法能够分析部分锚固的剪力墙的承载能力。为了正确应用塑性方法,必须确保护套-框架接头的延展性,尤其要避免底轨的脆性破坏。在部分锚固的剪力墙中,前螺柱并未完全锚固以抵抗隆起,并且在护套至框架的连接处沿着靠近前螺柱的护套段中的底部导轨产生了相应的系紧力。接头中的这些束紧力可能会引入许多可能的脆性破坏模式或底轨的可维修性问题,需要消除或限制这些问题才能应用塑性方法。本文介绍了针对锚定螺栓的垫圈或轴承板进行适当设计的实验结果,以避免底部导轨裂开和垫圈凹痕过多。研究了双面和单面护套以及不同位置的地脚螺栓的标本。关于底部导轨的分离,测试表明,失效载荷取决于从垫圈边缘到底部导轨的已加载边缘的距离。对于由于锚定螺栓的垫圈的应力引起的大变形,垫圈的尺寸是最重要的参数。测试结果表明,大型垫圈的承载强度低于Eurocode 5提出的承载强度。因此,在本文中,建议使承载强度与垫圈的直径或侧边长度成反比。然后,发现与测试结果良好的一致性。结果表明,由于分裂而导致的故障是决定性的设计模式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号