摘要

Based on the development of Planar Waveguide Fluorescence Immuno-sensor (PWFI) and preparation of immuno-chip, an environmental pollutant, microcystin-LR, was detected as a sample substance. The experiment results showed that the immtmo-sensor was sensitive for MC-LR detection. Calibration curve obtained for MC-LR detection had LOD of 0.06 μg/L and QOD range of 0.10-3.6 μg/L, which reveals the potential ability to evaluate the safety of drinking water.
机译:基于平面波导荧光免疫传感器(PWFI)的发展和免疫芯片的制备,检测到环境污染物微囊藻毒素-LR作为样品物质。实验结果表明,immtmo传感器对MC-LR检测敏感。用于MC-LR检测的校准曲线的LOD为0.06μg/ L,QOD范围为0.10-3.6μg/ L,这显示了评估饮用水安全性的潜在能力。