首页> 外文会议>International Conference on Building Energy and Environment >Energy Efficiency of Double-skin Facade in Office Buildings of Shanghai
【24h】

Energy Efficiency of Double-skin Facade in Office Buildings of Shanghai

机译:上海市办公楼双层外立面的能效

获取原文

摘要

Glass facade office buildings are becoming more popular in China,but their impact on energy consumption is little researched.The double-skin facade presents a possible solution for energy efficiency in highly glazed buildings for China.In this paper,a comparative analysis of heating and cooling loads of a typical office cell with double-skin fa(c)ade is made against a single-skin fa(c)ade and a traditional window-wall fa(c)ade in the climatic condition of Shanghai.The coupling of the spectral optical model GLSIM and the dynamic thermal model HTB2 is used as the simulation method.Simulation results indicate that both heating and cooling energy savings can be achieved using a reflective double-skin fa(c)ade with the appropriate choice of ventilation method.
机译:玻璃幕墙办公楼在中国越来越流行,但对能耗的影响却鲜有研究。双层玻璃幕墙为中国高玻璃建筑的能源效率提供了一种可能的解决方案。在上海的气候条件下,典型的带有双层皮肤fa(c)ade的办公单元的制冷负荷是针对单层皮肤fa(c)ade和传统的窗墙fa(c)ade得出的。光谱光学模型GLSIM和动态热模型HTB2被用作仿真method.Simulation结果表明,加热和冷却的能量积蓄可以使用带通风方法的适当选择的反射双层FA(c)中ADE来实现。