In order to check the electric field distribution of polymer line post insulator, we performed electric field simulation according to state of water droplets. Water droplets use sea water contaminant. The water droplets may appear in different forms and sizes, therefore the form is defined by the angle shape between the surface of the water droplet. The water droplet may measure from less than 90 degree (hydrophilic) up to greater than 90 degree (hydrophobic), depending on the properties of insulator surface. This paper describes numerical analysis calculation of electric fields and its potential distribution in the surrounding of water droplets on an insulator surface. Electric field analysis is performed with change of contact angle, number and distance between water droplets. The computation results show that the electric field close to the water droplets tends to be higher as number of water droplets increases. The electric field fluxes were also affected slightly by the contact angle.
机译:为了检查聚合物线绝缘子的电场分布,我们根据水滴的状态进行了电场模拟。水滴会使用海水污染物。水滴可能以不同的形式和大小出现,因此该形式由水滴表面之间的角度形状定义。根据绝缘子表面的特性,水滴的测量范围可以从小于90度(亲水)到大于90度(疏水)。本文描述了绝缘体表面水滴周围电场及其电位分布的数值分析计算。通过改变水滴之间的接触角,数量和距离来进行电场分析。计算结果表明,随着水滴数量的增加,靠近水滴的电场趋向于更高。电场通量也受到接触角的轻微影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号