首页> 外文会议>Aerospace testing seminar >CALIBRATION OF A LARGE CHANNEL COUNT DATA ACQUISITION SYSTEM
【24h】

CALIBRATION OF A LARGE CHANNEL COUNT DATA ACQUISITION SYSTEM

机译:大通道数数据采集系统的校准

获取原文

摘要

Lockheed Martin's Sunnyvale facility operates 4 large thermal vacuum chambers, each having adata channel count in excess of 700 channels. Recently, the data acquisition systems attached tothese chambers were upgraded. The new system was expected to meet an accuracy specificationof +- 1.5 degree C over a temperature range of 200 to -200 degree C. The initial installationfailed to meet this specification for roughly 20 percent of its data channels. This paper discussesthe sources of error that caused the system to fail calibration and how they were addressed.
机译:洛克希德·马丁公司位于桑尼维尔的工厂经营着4个大型热真空室,每个室都有一个 数据通道数超过700个通道。最近,数据采集系统附属于 这些房间升级了。新系统有望达到精度规格 在200至-200摄氏度的温度范围内为+-1.5摄氏度。初始安装 大约有20%的数据通道无法满足此规范。本文讨论 导致系统无法通过校准的错误源以及如何解决这些错误。