首页> 外文会议>Indoor Air 2005 >PERCEIVED INDOOR ENVIRONMENT AND SICK BUILDING SYNDROME (SBS) IN RELATION TO ENERGY SAVING BY SEASONALLY ADAPTED VENTILATION: A ONE YEAR INTERVENTION STUDY IN DWELLINGS
【24h】

PERCEIVED INDOOR ENVIRONMENT AND SICK BUILDING SYNDROME (SBS) IN RELATION TO ENERGY SAVING BY SEASONALLY ADAPTED VENTILATION: A ONE YEAR INTERVENTION STUDY IN DWELLINGS

机译:与季节适应通风相关的室内环境和病房综合症(SBS)感知:对住宅的一年干预研究

获取原文

摘要

The aim was to study if a 25-30% reduction of outdoor ventilation flow, during heating season, influenced the perception of the indoor environment. This was done in a one-year cross-over intervention study in 44 subjects in a multi-family building. During the first heating season, one part of the building (A) got a reduced flow during theheating season (0.4-0.5 ACH) while the other part (B) had constant flow (0.5-0.8 ACH). Next season the ventilation principals were shifted. The two ventilation principals showed small differences due to relative air humidity, room temperature and mean carbon dioxide (CO2) concentration. There was a significant increase of perceived stuffy odour at reduced outdoor airflow and the indoor air quality was perceived as poorer. No significant influence on SBS symptoms could be detected. In conclusion when evaluate new ventilation systems it is important to combine technical measurements with a longitudinal evaluation of occupant's reactions.
机译:目的是研究供暖季节室外通风流量减少25-30%是否会影响室内环境感知。这项为期一年的交叉干预研究是在多户家庭建筑中对44位受试者进行的。在第一个供暖季节,建筑物(A)的一部分在供暖季节(0.4-0.5 ACH)流量减少,而另一部分(B)则有恒定流量(0.5-0.8 ACH)。下个季节换气的原则。由于相对空气湿度,室温和平均二氧化碳(CO2)浓度,这两个通风原理显示出很小的差异。在室外空气流量减少的情况下,感觉到的闷气气味显着增加,并且室内空气质量被认为较差。没有发现对SBS症状有明显影响。总之,在评估新的通风系统时,将技术测量与对乘员反应的纵向评估结合起来很重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号