Mathis effusivity sensor package (ESP) system measures effusivity of materials, based on the transient hot strip technique. It is used mainly as an online or inline process monitoring and control system in various industries such as pharmaceutical and cosmetics. Examples of applications are real time monitoring of the uniformity of blended powders in motion, and monitoring of drying processes. Presently, the system is being modified for applications that require thermal conductivity measurements up to 40 W/mK and temperature up to 200°C. The system combines a reduced calibration technique with improved algorithms that compensate for variations in sensor temperature, thus enabling reliable effusivity measurements seamlessly in a wide range of temperatures. In this paper, some aspects of the system are reviewed. The review includes theoretical principles, design considerations for the sensor and system, sensor calibration, uncertainty evaluation of measurements and finally typical experimental results are reported.
机译:基于瞬态热带技术,Mathis活性传感器封装(ESP)系统测量材料的热性。它主要用于各种行业的在线或内联流程监控系统,如制药和化妆品。应用的实例是对运动中混合粉末的均匀性的实时监测,以及监测干燥过程。目前,该系统正在修改用于需要导热性测量的应用,该应用可达40瓦/ mk和温度高达200°C。该系统将减少的校准技术与改进的算法相结合,该算法补偿了传感器温度的变化,从而在各种温度范围内无缝地进行可靠的积液测量。在本文中,综述了系统的一些方面。审查包括理论原则,传感器和系统的设计考虑,传感器校准,测量不确定性评估以及最终典型的实验结果。