首页> 外文会议>Proceedings of the Combustion Institute >EFFECT OF INJECTION LOCATION ON THE EFFECTIVENESS OF AN ACTIVE CONTROL SYSTEM USING SECONDARY FUEL INJECTION
【24h】

EFFECT OF INJECTION LOCATION ON THE EFFECTIVENESS OF AN ACTIVE CONTROL SYSTEM USING SECONDARY FUEL INJECTION

机译:注射位置对使用二次燃料注射的主动控制系统效率的影响

获取原文

摘要

The effect of secondary fuel injection location on the effectiveness of active combustion control was studied in an atmospheric pressure, laboratory-scale dump combustor operating on natural gas with a nominal heat release rate of 75 kW. The combustor provided for secondary fuel injection from three different locations. The effectiveness of both open- and closed-loop control was found to be strongly dependent on the secondary fuel injection location. To understand this behavior, CO_2 chemiluminescence imaging measurements were made of the spatial and temporal heat release distribution in the combustor, both to characterize the evolution of the heat release distribution during unstable combustion and to characterize the heat release produced by the injection of secondary fuel. The results indicate that the most effective approach to preventing unstable combustion is not necessarily to add heat in a manner which is out of phase with the instability but that effective control can also be achieved by disrupting the mechanism that is driving the instability. These results serve to illustrate that gaining an understanding of the phenomenology of the instability is a critical step in designing and optimizing an active combustion control system.
机译:在大气压,实验室规模的倾卸式燃烧器上,使用以标称放热率为75 kW的天然气运行,研究了二次燃料喷射位置对主动燃烧控制效果的影响。燃烧器提供了从三个不同位置进行二次燃料喷射的功能。发现开环和闭环控制的有效性在很大程度上取决于二次燃料喷射位置。为了了解这种行为,对燃烧器中的空间和时间放热分布进行了CO_2化学发光成像测量,以表征不稳定燃烧期间放热分布的演变,并表征由二次燃料喷射产生的放热。结果表明,防止不稳定燃烧的最有效方法不一定是以与不稳定状态异相的方式添加热量,而是还可以通过破坏驱动不稳定状态的机制来实现有效控制。这些结果说明,了解不稳定性现象是设计和优化主动燃烧控制系统的关键步骤。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号