Korean next generation reactor (KNGR), which is to be designed as a standard evolutionary advanced light water reactor (ALWR) in Korea, has been developed from 1992 as one of long-term governement projects. The major characteristics of the KNGR are as follows; KNGR is 2-loop PWR and its design life time is 60 years. The CDF and the DFF will be much lower than 10~(-5)/RY and 10~(-6)/RY, respectively. For the design improvement, KNGR adopted inconel-690 as a steam generator tube material, four train ECCS, refueling water storage tank inside containment, and double cylindrical concrete containment. For more reliable and easier control, compact workstations have been adopted in the design of main-control complex and digital I&C technology is used for protection, control, and monitoring. In addition, KNGR has some passive design features such as fluidic device in safety injection tank, passive secondary condensing system, and passive auto-catalytic hydrogen recombiner to enhance safety.