首页> 外文会议>Industrial waste conference >Optimization of halogen dose for biofilm control
【24h】

Optimization of halogen dose for biofilm control

机译:优化卤素剂量以控制生物膜

获取原文

摘要

Two quasi closed recirculating systems (A and B) were operated in parallel in an attempt to optimize the halogen dose and residual required for biofouling control and/or the destruction of an established biofilm. Each system contained a deposit accumulation testing system (DATS~(TM)), from Bridger Scientific (heat exchanger, flow controller, and microprocessor for automated data collection), corrosion coupons, a differential pressure section (4' length), a 10 gallon conical bottom reservoir, and a centrifugal pump. Bromine (system A) and chlorine (system B) were studied under varying conditions (pH 7.6 and 8.6; nitrogen source ammoniumitrate) with three or four halogen doses being examined for each set of conditions.
机译:两个准封闭式再循环系统(A和B)并行运行,以尝试优化生物污垢控制和/或破坏已形成的生物膜所需的卤素剂量和残留量。每个系统都包含来自Bridger Scientific的沉积物堆积测试系统(DATS〜(TM))(热交换器,流量控制器和用于自动数据收集的微处理器),腐蚀试样,压差部分(4'长度),10加仑圆锥形底部储液罐和离心泵。在不同条件下(pH 7.6和8.6;氮源铵/硝酸盐)对溴(系统A)和氯(系统B)进行了研究,每种条件下均检查了三或四个卤素剂量。