首页> 外文会议>Conference on Electrical Insulation and Dielectric Phenomena >Onset voltage of negative corona in point-cup gaps
【24h】

Onset voltage of negative corona in point-cup gaps

机译:负电晕的发病电压在点杯间隙中

获取原文

摘要

In this paper, the onset voltage of negative corona is theoretically predicted for point-cup gaps positioned in air. The method of calculation is based on the criterion developed for the formation of repetitive negative corona Trichel pulses. Field distributions are determined through charge simulation method coupled with least-square error method for optimal charge distribution and accurate field computation. Different gap dimensions are studied. Accurate distributions, not only for the potential but also for the electric field have been obtained throughout the entire interelectrode space. Negative onset voltage of corona is calculated at different gap dimensions and different air pressures. The values of calculated onset voltages agreed well with those measured experimentally within 5 %.
机译:在本文中,理论上预测了位于空气中的点杯间隙理论上预测了负电晕的起始电压。计算方法基于为形成重复负电晕脉冲而开发的标准。通过对最小电荷分布和精确场计算的电荷仿真方法确定磁场分布。研究了不同的间隙尺寸。在整个电极间空间中获得了准确的分布,不仅用于电势,而且还获得了电场。电晕的负发作电压在不同的间隙尺寸和不同的空气压力下计算。计算的发作电压的值与实验在5%以内测量的那些相同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有