首页> 外文会议>Medical Imaging VI: Image Processing >Determination of left ventricular ejection fraction in technetium-99m-methoxy isobutyl isonitrile radionuclide angiocardiography
【24h】

Determination of left ventricular ejection fraction in technetium-99m-methoxy isobutyl isonitrile radionuclide angiocardiography

机译:m- 99m-甲氧基异丁基异腈放射性核素血管造影中左心室射血分数的测定

获取原文
获取原文并翻译 | 示例

摘要

Abstract: Abnormal left ventricular function is a diagnostic indication of cardiac disease. Left ventricular function is most commonly quantified by ejection fraction measurements. This paper presents a novel approach for the measurement of left ventricular ejection fraction (L VEF) using the recently introduced myocardial imaging agent, technetium-99m methoxy isobutyl isonitrile ($+99m$/Tc- sestamibi). The approach utilizes computer image processing techniques to determine L VEF in equilibrium $+99m$/Tc-sestamibi multiple gated radionuclide angiography (RNA). Equilibrium RNA is preferred to first-pass RNA techniques due to the higher signal- to-noise ratio of equilibrium RNA resulting from longer image acquisition times. Data from 23 patients, symptomatic of cardiac disease, indicate that L VEFs determined using this radionuclide technique correlate well with contrast x-ray single plane cineangiography (r $EQ 0.83, p $LS 0.0000003). !32
机译:摘要:左心室功能异常是心脏病的诊断指标。左心室功能最常见的是通过射血分数测量来量化。本文介绍了一种使用最近推出的心肌显像剂tech-99m甲氧基异丁基异腈($ 99m $ / Ts-sestamibi)测量左心室射血分数(L VEF)的新方法。该方法利用计算机图像处理技术来确定平衡中的L VEF $ + 99m $ / Tc-司他米比多门放射性核素血管造影(RNA)。平衡RNA比首过RNA技术优先,因为更长的图像采集时间会导致平衡RNA的信噪比更高。来自23例有心脏病症状的患者的数据表明,使用这种放射性核素技术测定的L VEF与X线对比单平面血管造影显着相关(r $ EQ 0.83,p $ LS 0.0000003)。 !32

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号