Researched on the probe’s diameter error of the Articulated Arm Coordinate Measuring Machine (AACMM) in themeasuring process. Based on the analysis of the influence of the error source on the accuracy of the probe, the influence ofthe contact force on the measuring diameter of the probe was analyzed emphatically. It was proposed to use the CoordinateMeasuring Machine (CMM) to identify the probe diameter error of the AACMM and apply the least square method tocompensate the probe diameter error. The results show that the research method has certain feasibility. The maximum errorof the length measurement is reduced by about 47 um. The average error is reduced from 0.0315 mm to 0.0046 mm, whichimproved the measurement accuracy of the AACMM.
机译:研究了铰接臂坐标测量机(AACMM)在测量过程中的直径误差。在分析误差源对测头精度的影响的基础上,着重分析了接触力对测头直径的影响。建议使用坐标测量机(CMM)来识别AACMM的探针直径误差,并应用最小二乘法来补偿探针直径误差。结果表明,该研究方法具有一定的可行性。长度测量的最大误差降低了约47 um。平均误差从0.0315毫米减小到0.0046毫米,从而提高了AACMM的测量精度。

著录项

  • 来源
  • 会议地点 1996-756X;0277-786X
  • 作者

    Cai Zeliang; Luo Zai; Liu Hui;

  • 作者单位

    China Jiliang University, Xueyuan Street, Xiasha Higher Education Zone, Jianggan District,Hangzhou, Zhejiang, China;

    China Jiliang University, Xueyuan Street, Xiasha Higher Education Zone, Jianggan District,Hangzhou, Zhejiang, China luozai@cjlu.edu.cn;

    China Jiliang University, Xueyuan Street, Xiasha Higher Education Zone, Jianggan District,Hangzhou, Zhejiang, China 392102168@qq.com;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号