INFLUENCE OF ASYMMETRY IN THE WORKING ELECTRODES ON NOISE RESISTANCE MEASUREMENTS

机译:工作电极中的不对称性对抗噪声性的影响

获取原文
获取原文并翻译 | 示例

摘要

The significance of electrochemical noise measurements in cells containing two identical electrodes kept at the same potential has been clearly established. However, when the electrodes are of different materials or when a bias voltage is applied between them, it is not clear what information the measurement of the noise impedance yields. The purpose of this paper is to develop the theory of asymmetric cell measurements, and to compare the predictions of the model with experimental results obtained for four asymmetric systems.
机译:已经清楚地确定了在包含两个保持相同电位的相同电极的电池中进行电化学噪声测量的重要性。然而,当电极由不同材料制成或在它们之间施加偏置电压时,不清楚测量出的噪声阻抗信息是什么。本文的目的是发展不对称单元测量的理论,并将模型的预测与针对四个不对称系统获得的实验结果进行比较。