【24h】

INFLUENCE OF MAGNIFIERS ON OCULAR EXPOSURE LEVELS

机译:放大镜对眼部暴露水平的影响

获取原文
获取原文并翻译 | 示例

摘要

From the beginning of laser safety standards it was taken into account that the ocular hazard may be increased when optical aided viewing is assumed. Especially, for highly divergent beams this kind of hazard was recognized when analyzing the potential hazard for inspecting optical fiber tips. Up to now different methods and measurement conditions were published in the IEC standard to cover all products that emit divergent laser beams. Each new version of the standard increased the effort on the measurement setup, which finally leads to the ongoing discussion about the current Condition 2 (loupe condition) in IEC 60825-1 (2007). On the basis of numerous measurements of different divergent sources this paper shows that Condition 2 is only relevant for small sources and could be simplified or even eliminated from part 1 of the standard series IEC 60825.
机译:从激光安全标准的开始就考虑到,当采用光学辅助观察时,可能会增加眼睛的危害。特别是,对于高度发散的光束,在分析检查光纤尖端的潜在危险时已认识到这种危险。到目前为止,IEC标准中发布了不同的方法和测量条件,以涵盖所有发出发散激光束的产品。该标准的每个新版本都增加了测量设置的工作量,最终导致对IEC 60825-1(2007)中当前条件2(放大镜条件)的持续讨论。根据对不同发散源的大量测量,本文表明条件2仅与小型源相关,可以从IEC 60825标准系列的第1部分中简化甚至消除。