【24h】

Influence of concrete slabs on lateral torsional buckling of steel beams

机译:混凝土板对钢梁横向扭转屈曲的影响

获取原文
获取原文并翻译 | 示例

摘要

The use of pre-cast concrete floor slabs in steel framed structures is quite common. A non-connected concrete slab on top of a beam will provide some restraint to the beam. It may even be that the restraint provided by the floor slab prevents lateral torsional buckling. To investigate the restraining effect of a concrete slab on the top flange of a steel beam subject to lateral torsional buckling, two experimental load tests were performed. The first test is a test where a steel beam with lateral restraints at the supports only (fork conditions), was loaded in four point bending. In a second test, a single 1.2 m wide non-connected concrete slab was placed on a strip of rubber at mid span of the steel beam. The tests were carried out on 7.2 m long IPE240, S235 beams subject to the same loading conditions. The test results have been compared with results obtained from Finite Element simulations and theoretical analyses.
机译:在钢框架结构中使用预制混凝土楼板非常普遍。梁顶部的未连接混凝土板将为梁提供一定的约束。甚至可能是楼板提供的约束阻止了横向扭转屈曲。为了研究混凝土板对钢梁顶翼承受侧向扭转屈曲的约束作用,进行了两个实验载荷试验。第一个测试是在四点弯曲中加载仅在支撑件上有侧向约束的钢梁(叉形条件)的测试。在第二项测试中,将一块1.2 m宽的未连接混凝土板放在钢梁中间跨度的橡胶条上。在相同的载荷条件下,对7.2 m长的IPE240,S235梁进行了测试。测试结果已与有限元模拟和理论分析获得的结果进行了比较。