The ability of a gas chromatographic (GC) column to separate two compounds is determined by its analytical resolution. The height equivalent to a theoretical plate (HETP) is given by HETP=2D_g/u+C_su+C_Mu where D_g is the diffusion coefficient in the gas phase, and C_s and C_M are the resistances to mass transfer in the gas and liquid phases, respectively. For a rectangular column, the average linear velocity u is given by u=1/(8bd)_(-b-d)∫∫~(+b+d)[((x~2-b~2)(y~2-d~2))/((x~2-b~2)+(y~2-d~2))]dxdy1/η(dP)/(dz) where 2b and 2d are the width and height of the column, η is the viscosity of the carrier gas, and dP/dz is the pressure gradient along the column. Whenever bd, u can be approximated by u=-[A_1(b~2d~2)/(b~2+d~2)+A_2(b~4d~4)/((b~2+d~2)~3)+...+A_n(b~(2n)d~2n)/((b~2+d~2)~(2n-1))+...]1/η(dP)/(dz) where A_n are constants whose values depend on the type and level of approximation.
机译:气相色谱(GC)色谱柱分离两种化合物的能力取决于其分析分辨率。等效于理论塔板(HETP)的高度由HETP = 2D_g / u + C_su + C_Mu给出,其中D_g是气相中的扩散系数,C_s和C_M是气相和液相中对传质的阻力,分别。对于矩形柱,平均线速度u由u = 1 /(8bd)_(-bd)∫∫〜(+ b + d)[((x〜2-b〜2)(y〜2- d〜2))/(((x〜2-b〜2)+(y〜2-d〜2))] dxdy1 /η(dP)/(dz)其中2b和2d是列的宽度和高度,η是载气的粘度,dP / dz是沿色谱柱的压力梯度。每当b >> d时,u可以由u =-[A_1(b〜2d〜2)/(b〜2 + d〜2)+ A_2(b〜4d〜4)/((b〜2 + d 〜2)〜3)+ ... + A_n(b〜(2n)d〜2n)/(((b〜2 + d〜2)〜(2n-1))+ ...] 1 /η(dP )/(dz)其中A_n是常数,其值取决于近似的类型和水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号