Flow meter is calibrated by flow standard facilitices by master meter method, is becoming trend of flow meter calibration method. The research of the calibration method and evaluation of uncertainty are focused in science field. This paper analyzes the influence facts of the process of calibration of flow meter by standard meter method around the calibration of turbine flow meter by standard turbine flow meter, establishes the mathematical model and give out the evaluation method and program of calibration uncertainty. The method was verified by test.
机译:流量计通过流量标准仪通过主仪表法进行校准,正在成为流量计校准方法的趋势。校准方法和不确定度评估的研究是科学领域的重点。本文围绕标准涡轮流量计对涡轮流量计的校准,分析了标准流量计对流量计的校准过程的影响因素,建立了数学模型,给出了校准不确定度的评估方法和程序。该方法已通过测试验证。