首页> 外文会议>Innovation in power generation measurement and control >Improved Accuracy of NaturalGas Turbine Flow Meters Using Carbon Dioxide as theCalibration Media
【24h】

Improved Accuracy of NaturalGas Turbine Flow Meters Using Carbon Dioxide as theCalibration Media

机译:使用二氧化碳作为校准介质的天然气涡轮流量计的改进精度

获取原文
获取原文并翻译 | 示例

摘要

Recent AGA research has found differences between calibration and actual natural gas flowing conditions cause turbine meter measurement errors commonly 1/4 to 1%. In some cases errors were as high as 3 to 5%. The effect was unique to each meter, meaning that calibration at actual gas flowing conditions is necessary to ensure accurate measurement. A novel and new calibration process using CO2 to replicate natural gas flowing conditions addresses barriers to representative natural gas calibration over a wide range of industry operating conditions. This paper will overview the problem with natural gas turbine meter calibration, summarize researchrnvalidating the use of carbon dioxide for natural gas meter calibration, and present early comparative results from a CO2 calibration facility commissioned in the spring of 2005.
机译:最近的AGA研究发现,校准和实际天然气流动条件之间的差异会导致涡轮流量计的测量误差通常为1/4至1%。在某些情况下,误差高达3%到5%。每个仪表的效果都是独特的,这意味着必须在实际的气体流动条件下进行校准,以确保精确的测量。使用CO2复制天然气流动条件的新颖新颖的校准过程解决了在广泛的工业运行条件下进行代表性天然气校准的障碍。本文将概述天然气涡轮流量计校准中的问题,总结验证使用二氧化碳进行天然气流量计校准的研究,并提供2005年春季投入使用的CO2校准设施的早期比较结果。