首页> 外文会议>Heat-air-moisture transport : Measurements and implications in buildings >Assessment of Energy Rating of Polyurethane Spray Foam Walls: Procedure and Interim Results
【24h】

Assessment of Energy Rating of Polyurethane Spray Foam Walls: Procedure and Interim Results

机译:聚氨酯喷涂泡沫墙能效等级评估:程序和中期结果

获取原文
获取原文并翻译 | 示例

摘要

The application of polyurethane spray foam (SPF) insulation in buildings provides a durable and efficient thermal barrier. The industry is also promoting the SPF as an effective air barrier system in addition to its thermal insulation characteristics. In an effort to address these issues, a consortium of SPF manufacturers and contractors, jointly with the National Research Council of Canada's Institute for Research in Construction conducted an extensive research project to assess the thermal and air leakage characteristics of SPF walls as well as conventional wall assemblies. The objective is to develop analytical and experimental procedures to determine a wall energy rating (WER) that captures both the thermal and airleakage performance of a wall assembly. The experimental part included two streams of testing: (1) To determine the wall air leakage rate at different conditions and (2) their thermal resistance, fl-value, at different temperature differences. An analytical procedure was also developed to calculate WER by combining the heat loss due to thermal transmission and that due to air leakage with the aim of arriving at WER. Six conventional full-scale wood frame wall assemblies were built, two with glass fiber batts and of four with medium density SPF. Some walls were constructed without penetrations and others were built with penetrations. The testing regime included: (ⅰ) Initial testing of air leakage and thermal resistance; (ⅱ) conditioning in the dynamic wall test facility according to an established routine; and (ⅲ) retesting for air leakage and thermal resistance. This paper presents the results of six walls included in this project. The focus of this paper will be on presenting a brief summary of the project objective, testing protocol, and the theoretical approach to determine the WER number for the six walls.
机译:聚氨酯喷涂泡沫(SPF)隔热材料在建筑物中的应用提供了持久而有效的隔热层。除了其绝热特性,业界还正在推广SPF作为有效的空气屏障系统。为了解决这些问题,SPF制造商和承包商的财团与加拿大国家建筑研究研究院国家研究委员会联合进行了一项广泛的研究项目,以评估SPF墙以及常规墙的热和空气泄漏特性组件。目的是开发分析和实验程序,以确定可同时捕获壁组件的热性能和漏气性能的壁能额定值(WER)。实验部分包括两个测试流:(1)确定在不同条件下的壁漏气率;(2)在不同温差下的热阻fl值。为了达到WER,还开发了一种分析程序来计算WER,方法是将热传递和空气泄漏引起的热量损失相结合。建造了六个常规的全尺寸木框架墙组件,其中两个带有玻璃纤维毡,另外四个带有中等密度SPF。有些墙是没有穿透的,而另一些是带有穿透的。测试方案包括:(ⅰ)空气泄漏和热阻的初始测试; (ⅱ)按照既定程序在动态墙测试设备中进行调节; (ⅲ)重新测试漏气和热阻。本文介绍了此项目中包含的六面墙的结果。本文的重点将是对项目目标,测试协议以及确定六面墙的WER数的理论方法进行简要概述。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号