At Habanero site in Cooper-Basin EGS field in South Australia, the first circulation test was conducted between injection well Habanero #1 and production well Habanero #3 in December 2008. As part of this test, a tracer test was performed in order to characterize the connection between these two wells and estimate reservoir volume. The tracer test started on 17 December 2008 and 50 kg of the tracer uranine (sodium salt of fluorescein) and 100 kg of the tracer 1,3,5-naphthalene trisulfonate (1,3,5-nts) were injected into Habanero #1.rnThere was tracer breakthrough on 21 December, 4 days after tracer injection. Tracer concentration reached peak value around 26 December, 9 days after the start of injection. The distance between Habanero #1 and Habanero #3 is about 500 meters and the average flow rate in closed-loop system was about 14 kg/second. Based on this flow rate, the tracer breakthrough volume was estimated to be about 4,000 m~3 and the peak volume about 9,000 m~3, the calculated tracer-swept pore volume was 18,500 m~3.
机译:在南澳大利亚州Cooper-Basin EGS油田的Habanero现场,于2008年12月在注入井Habanero#1和生产井Habanero#3之间进行了首次循环测试。作为该测试的一部分,进行了示踪剂测试以表征这两个井之间的联系并估算储层容量。示踪剂测试于2008年12月17日开始,将50千克示踪剂尿素(荧光素钠)和100千克示踪剂1,3,5-萘三磺酸盐(1,3,5-nts)注入Habanero#1中。 .r示踪剂注入后4天,12月21日有示踪剂突破。示踪剂浓度在注射开始后9天左右的12月26日左右达到峰值。 Habanero#1和Habanero#3之间的距离约为500米,闭环系统中的平均流量约为14 kg /秒。根据该流速,示踪剂穿透体积估计为约4,000 m〜3,峰值体积约为9,000 m〜3,计算出的示踪剂扫掠孔体积为18,500 m〜3。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号