首页> 外文会议>Energy efficient amp; healthy buildings in sustainable cities >HOT-BOX TESTS FOR BUILDING ENVELOPECONDENSATION ASSESSMENT
【24h】

HOT-BOX TESTS FOR BUILDING ENVELOPECONDENSATION ASSESSMENT

机译:建筑箱体凝结评估的热箱测试

获取原文
获取原文并翻译 | 示例

摘要

A common architectural feature of curtain wall facades is constituted by a transparent double-glazing unitrnmounted in front of a recessed interior metal panel. It is typically installed in spandrel areas, where it’s requiredrnto provide to the fa?ade not only surface consistency but also depth.rnTo evaluate condensation risk on this type of envelope element, an experimental program has being carried outrnon a typical fa?ade panel (Shadow-box) provided by Permasteelisa. The specimen performances wererninvestigated using a guarded hot-box and an extensive 3-dimensional temperature monitoring has been carriedrnout under various steady-state winter conditions. The temperature on the glazing and surrounding frames hasrnbeen compared to the dew-point temperatures. Particular emphasis has been given to the pressure equalizationrnbetween the outdoor environment and the inner space of shadow-box. Moreover the applicability of therntemperature factor, proposed in European Standards, is also investigated as condensation risk indicator on wallrninternal surface.
机译:幕墙外墙的常见建筑特征是由安装在凹陷的内部金属面板前的透明双层玻璃构成。它通常安装在跨距区域,不仅需要提供外观一致性,而且还需要提供外观深度。为评估此类信封元件的凝结风险,已经在典型的外观面板上进行了实验程序(影盒)由Permasteelisa提供。使用带保护的热箱对样品的性能进行了研究,并在各种稳态冬季条件下进行了广泛的三维温度监控。与露点温度相比,玻璃和周围框架的温度已经降低。特别强调了室外环境与暗箱内部空间之间的压力平衡。此外,还研究了欧洲标准中提出的温度因数的适用性,作为壁内表面上的凝结风险指标。