This paper presents the results of a series of specially designed experiments to study moisture transport acrossrnbonded or natural contact interfaces between building materials. The results showed that the bonded or naturalrncontact interfaces between aerated concrete and mortar are imperfect hydraulic contact. In addition, all the testedrncases were simulated using a numerical model. The results showed that there was good agreement betweenrnexperimental results and predictions made by the model. Based on predictions of the model and experimentalrnresults, the present study found that imperfection of an interface between different types of building materialsrnsignificantly depends on the direction of the moisture transport. Moreover, the bonded interface between AC andrnPCLMS showed similar characteristics as the natural contact interface between AC and PCLMS: indicating thatrnthe bonding has no critical effect on moisture transport, and the bonded interface can be approximately treated asrnthe natural contact interface.
机译:本文介绍了一系列专门设计的实验的结果,这些实验研究了建筑材料之间跨键合或自然接触界面的水分传输。结果表明,加气混凝土与砂浆之间的粘结或自然接触界面水力接触不完善。另外,所有被测试的案例都使用数值模型进行了模拟。结果表明,实验结果与模型预测值吻合良好。基于模型的预测和实验结果,本研究发现,不同类型的建筑材料之间的界面的缺陷很大程度上取决于水分传输的方向。此外,AC和PCLMS之间的键合界面表现出与AC和PCLMS之间的自然接触界面相似的特征:表明键合对水分传输没有关键影响,并且可以将键合界面近似视为自然接触界面。