首页> 外文会议>Energy efficient amp; healthy buildings in sustainable cities >PERFORMANCE STUDY ON HYBRID VENTILATIONSYSTEM WITH AIR SUPPLY FROM CRAWL SPACEUSING A TEST HOUSE
【24h】

PERFORMANCE STUDY ON HYBRID VENTILATIONSYSTEM WITH AIR SUPPLY FROM CRAWL SPACEUSING A TEST HOUSE

机译:试验房爬网空间供气混合通风系统的性能研究。

获取原文
获取原文并翻译 | 示例

摘要

Ventilation is one of the most important measures to dilute indoor air pollutants. In order to maintain a clean indoor airrnenvironment, not only the total ventilation rate of the building but also the distribution of outdoor air to each area must be takenrninto consideration. A performance evaluation of the combined system of air supply from the crawl space and hybrid exhaustrnventilation with a small fan and damper has been investigated. This investigation was undertaken over a heating season using arnfull-scale test house. The ventilation airflow rate and the distribution to each room of the test house were measured by thernconstant concentration method. The influence of indoor-outdoor temperature difference on ventilation rate was also analyzed.rnAdditionally, the performance of this system was investigated by numerical analysis. The results revealed the performance ofrnthis ventilation system.
机译:通风是稀释室内空气污染物的最重要措施之一。为了保持清洁的室内空气环境,不仅必须考虑建筑物的总通风率,而且还应考虑室外空气向每个区域的分配。研究了从爬行空间供气和带有小型风扇和风门的混合排气换气组合系统的性能评估。这项研究是在采暖季节使用arnfull规模的测试室进行的。用恒定浓度法测量通风量和到测试室每个房间的分布。还分析了室内外温差对通风率的影响。此外,通过数值分析研究了该系统的性能。结果显示了该通风系统的性能。