首页> 外文会议>NACE International annual conference exposition;Corrosion98 >CONDITION EVALUATION FOR THE QUEEN ISABELLA CATHODIC PROTECTION PROJECT
【24h】

CONDITION EVALUATION FOR THE QUEEN ISABELLA CATHODIC PROTECTION PROJECT

机译:女王伊莎贝拉大教堂保护项目的状态评估

获取原文
获取原文并翻译 | 示例

摘要

Four different cathodic protection systems will be evaluated in tie beams and footings of the Queen Isabella Causeway which links South Padre Island to the mainland of Texas. This paper will describe the results of the pre-installation condition survey. The purpose of the pre-installation condition survey was to assess the condition of the structure and the feasibility of cathodic protection as a rehabilitation option. The condition evaluation included the following: visual inspection, delamination survey, cover survey, half-cell potential measurements and chloride content determination, At the footings, condition indicators evidencing more corrosion activity were found on the south footing than in other footings. This is due to the prevailing north wind and wave action in the area. At the tie beams, the construction joint is largely responsible for the deterioration as evidenced by the existence of cracks and high chloride contents. Electrical continuity, concrete cover survey and overall condition of the structure deem this structure as a good candidate for cathodic protection.
机译:伊莎贝拉女王堤道(Queen Isabella Causeway)的横梁和立脚将评估四种不同的阴极保护系统,该堤道将南帕德里岛与得克萨斯州大陆相连。本文将描述安装前状况调查的结果。安装前状况调查的目的是评估结构状况以及将阴极保护作为修复方案的可行性。条件评估包括以下内容:目视检查,分层调查,覆盖调查,半电池电位测量和氯化物含量测定。在该基础上,发现在南部基础上比其他基础上具有更多腐蚀活性的条件指标。这是由于该地区盛行北风浪。在连接梁处,施工缝隙是造成损坏的主要原因,这由裂缝和高氯化物含量的存在证明。电气连续性,混凝土覆盖层测量和结构的整体状况都认为该结构是阴极保护的良好选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号