Application of MR damper to base-isolated structures

机译:MR阻尼器在基础隔震结构中的应用

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a comprehensive study on the application of the MR damper to base-isolated building structures. It first proposes a simple semi-active control algorithm for a base-isolated structure with an MR damper. The algorithm, in which the MR damper's hysteresis shape is controlled, aims to reduce the isolator's displacement without increasing the acceleration responses of the upper structures. The second part of this paper covers the properties of an MR fluid and an MR damper developed for a base-isolated model structure. The damper has a nominal capacity of 40kN, which can be adjusted in accordance with the applied magnetic fields. In the test, the damper is subjected to cyclic sinusoidal displacements with different amplitudes', velocities and magnetic field intensities. The last part describes shaking table tests carried out using the MR damper and the base-isolated model structure. It is confirmed that the proposed semi-active control method is effective in reducing the isolator's displacement without increasing the acceleration responses.
机译:本文对MR阻尼器在基础隔震建筑中的应用进行了全面的研究。首先提出了一种用于带有MR阻尼器的基础隔震结构的简单半主动控制算法。该算法可控制MR阻尼器的磁滞形状,旨在减少隔离器的位移,而无需增加上部结构的加速度响应。本文的第二部分介绍了为基础隔离模型结构开发的MR流体和MR阻尼器的特性。该阻尼器的标称容量为40kN,可以根据所施加的磁场进行调节。在测试中,阻尼器会经受具有不同振幅,速度和磁场强度的周期性正弦位移。最后一部分介绍了使用MR阻尼器和基础隔离模型结构进行的振动台测试。可以确认,所提出的半主动控制方法在减小隔离器的位移而不增加加速度响应的情况下是有效的。