Evaluation of a Multispectral Diffuse Optical Spectroscopy Device for Assessment of Cardiometabolic Risk Related Alterations of Body Composition

机译:多光谱漫射光谱仪评估心脏代谢风险相关的身体成分变化的评估

获取原文
获取原文并翻译 | 示例

摘要

Cardiometabolic diseases encompass a combination of conditions which lead to an increase in the risk of cardiovascular disease and diabetes. With the increasing percentage of the population becoming overweight, it is important to diagnose when the excess adipose tissue becomes malign. The development of a safe, mobile, non-invasive method that would be easy to perform, and low-cost, but also would offer an accurate assessment of subcutaneous adipose tissue (SAT) both in lean and in obese persons is required. A prototype device using an optical method for measurement of the SAT in vivo has been developed, it contains multiple LEDs with four wavelengths (660nm, 780nm, 870nm, 940nm) distributed at various distances from the photodetector which allow different light penetration depths into the subcutaneous tissue. Five young healthy female students participated in the study; the measurements were performed on three body sites: calf, upper and lower abdomen. The backscattered light acquired with the prototype was compared to SAT measured with high resolution ultrasound imaging. The coefficient of variation indicated high reliability of the measurements. Statistically significant (from r=0.81 to r=0.95; p<0.05) correlation between intensity of backscattered light and SAT thicknesses for all four wavelength was observed, especially at source-detector distance 25mm. The novel device prototype has a potential to be a good alternative for conventional SAT measurement and assessment of cardiometabolic risk. Amultispectral approach can potentially increase precision and spatial resolution of SAT determination.
机译:心脏代谢疾病包括导致心血管疾病和糖尿病风险增加的多种病症。随着越来越多的人群变得超重,诊断过量的脂肪组织何时变得恶性很重要。需要开发一种安全,可移动,非侵入性的方法,该方法易于执行且成本低廉,而且还可以提供对瘦人和肥胖者皮下脂肪组织(SAT)的准确评估。已开发出使用光学方法测量体内SAT的原型设备,该设备包含多个LED,这些LED具有四个波长(660nm,780nm,870nm,940nm),这些LED分布在距光电探测器的不同距离处,从而允许不同的光穿透深度进入皮下组织。五名年轻健康的女学生参加了这项研究。测量是在三个身体部位进行的:小腿,上腹部和下腹部。将原型获得的反向散射光与通过高分辨率超声成像测得的SAT进行比较。变异系数表明测量的高度可靠性。观察到所有四个波长的背向散射光强度与SAT厚度之间的统计显着相关性(从r = 0.81到r = 0.95; p <0.05),尤其是在源探测器距离25mm处。这种新颖的设备原型有望成为常规SAT测量和评估心脏代谢风险的良好选择。多光谱方法可以潜在地提高SAT测定的精度和空间分辨率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号