Full-scale fire tests on upholstery sofa of different covers were conducted in the ISO 9705 room (3.6 mx2.4 mx2.4 m). The upholstery sofas had the same size, shape, frame, and foam, but different type of cover. Experimental measurements for each sofa included: Heat Release Rate, temperature history inside the fire-test room, also the mole fractions of carbon monoxide, carbon dioxide inside the exhaust duct. The relationships among the fire parameters were also studied. From the experiments it was found that each type of cover presented different fire hazards. But each of them had a rapid-fire growth. The results will provide references for building fire protection and fire safety design.
机译:在ISO 9705室(3.6 mx2.4 mx2.4 m)中对不同封面的沙发进行了全面的防火测试。室内装饰沙发具有相同的尺寸,形状,框架和泡沫,但覆盖物的类型不同。每个沙发的实验测量包括:放热率,耐火测试室内的温度历史记录,一氧化碳的摩尔分数,排气管内的二氧化碳。还研究了火灾参数之间的关系。从实验中发现,每种类型的覆盖物都具有不同的火灾隐患。但是他们每个人都有迅猛的成长。研究结果将为建筑防火和消防安全设计提供参考。