Autorefrigeration Near-Miss Incident at Equistar Chemicals, a Lyondell Company

机译:里昂戴尔公司Equistar Chemicals发生的自动制冷差错事件

获取原文
获取原文并翻译 | 示例

摘要

During the startup of the Equistar Chemicals Chocolate Bayou Olefins Plant following an eight day outage, an autorefrigeration near-miss incident occurred involving the unit deethanizer column. Autorefrigeration, i.e., the unintentional and uncontrolled phase change from a liquid to a vapor of a hydrocarbon that results in refrigeration, occurred when the deethanizer column was being reinventoried. The column's brittle fracture minimum allowable temperature was nearly reached. This autorefrigeration caused a failure of deethanizer reboilers resulting in extended downtime. Causes and corrective actions for this incident are presented.
机译:八天停运后,Equistar Chemicals Chocolate Bayou烯烃工厂启动期间,发生了涉及装置脱乙烷塔的自动制冷未命中事件。当对脱乙烷塔进行重新盘存时,发生了自动制冷,即从液体到碳氢化合物蒸气的意外和不受控制的相变,从而导致制冷。几乎达到了柱的脆性断裂最低允许温度。这种自动制冷导致脱乙烷塔再沸器故障,从而导致停机时间延长。介绍了此事件的原因和纠正措施。