The total pullout resistance of geogrid in a soil includes two components: (1) the interface friction resistance that takes place along longitudinal ribs and (2) the passive resistance that takes place against the front of transverse ribs. A series of pullout tests and analyses were conducted to quantify the contributions of the above two components to the overall pullout resistance. It was found that the mobilized passive resistance is much higher than the friction resistance under the same test conditions. Furthermore, the values of these two components are influenced by both pullout displacement and normal stress to a large extent.
机译:土工格栅在土壤中的总拉拔阻力包括两个组成部分:(1)沿纵向肋发生的界面摩擦阻力;(2)沿横向肋的前面发生的被动阻力。进行了一系列拔出测试和分析,以量化上述两个组件对整体拔出阻力的贡献。发现在相同的测试条件下,动员的被动电阻远高于摩擦电阻。此外,这两个分量的值在很大程度上受到拉拔位移和法向应力的影响。