This paper aims to investigate the thermal performance of extensive green roof under freefloating and air-conditioned conditions in winter.A field experiment was conducted on two full-scale rooms from 01/12/2014 to 17/12/2014 in Shanghai,one room was covered by green roof while the other was covered by common roof.Temperature distribution along the vertical direction of both roofs was recorded,and so were heat flux through the roofs as well as soil volumetric water ratio of green roof,local weather data was collected simultaneously.The results indicated that cooling effect of green roof was significant when solar radiation was strong,and green roof showed insulation effect only at night when the indoor air temperature was about 3℃ higher than that of common roof.Under free floating condition,temperature profile of green roof was like a saddle surface while common roof's profile was like a Mexican hat.And green roof's temperature profile pattern is similar to that of common roof under airconditioned condition.Energy balance analysis shows that net solar radiation and heat convection is the major heat gain for both roofs in winter,and net long wave radiation and evapotranspiration dissipate most heat gain for green roof while net long wave radiation is the main heat dissipation for common roof.
机译:本文旨在研究自由浮动和空调条件下冬季大面积绿化屋顶的热性能。2014年12月1日至2014年12月17日在上海的两个全尺寸房间进行了现场试验,其中一个房间记录屋顶沿垂直方向的温度分布,并记录通过屋顶的热通量以及屋顶的土壤体积水比,收集当地天气数据结果表明,在强烈太阳辐射下,绿色屋顶的降温效果显着,只有在夜间室内空气温度比普通屋顶高约3℃时,绿色屋顶才会表现出隔热效果。绿色屋顶的轮廓像一个马鞍形表面,而普通屋顶的轮廓像一个墨西哥帽。绿色屋顶的温度轮廓模式类似于普通屋顶下的温度轮廓。能量平衡分析表明,冬季两个屋顶的净热辐射和热对流是主要的热量吸收,净长波辐射和蒸散耗散了绿色屋顶的大部分热能,而净长波辐射是主要的热耗散。普通的屋顶。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号