【24h】

Experimental Study of Plate Freezer with the Ejector

机译:带喷射器的平板冷冻机的实验研究

获取原文
获取原文并翻译 | 示例

摘要

This paper introduced a kind of fluid supply system on ejector throttling.Comparing with the fluid supply system of thermodynamic expansion valve,this paper studied two kinds of fluid supply system on the freezing time,overall energy consumption and uniformity temperature distribute.The results showed that,in this working condition,the fluid supply system of ejector is 14% shorter than the thermodynamic expansion valve in freezing time,which reducing the power consumption by shortening the working time of compressor,condenser and other equipment.Meanwhile,Ejector can act like isentropy and recycle some expansion work,which could increase the refrigerant capacity of evaporator to save about 6.3% power consumption compared with the isoenthalpy throttling of thermodynamic expansion valve.The system can reducing IOoC temperature difference by avoiding two-phase flow fluid supply of the evaporator and reduce the flow resistance of refrigerant in evaporator.Thus,the quality of the product is improved.
机译:本文介绍了一种用于喷射节流阀的流体供应系统。与热力膨胀阀的流体供应系统相比,本文研究了两种流体供应系统的冻结时间,总体能耗和均匀温度分布。结果表明:在这种工作状态下,喷射器的流体供应系统在冻结时间上比热力膨胀阀短14%,从而通过缩短压缩机,冷凝器和其他设备的工作时间而减少了能耗。同时,喷射器可以起到熵的作用并进行一些膨胀工作,与热力膨胀阀的等焓节流相比,可以增加蒸发器的制冷量,从而节省约6.3%的功率。该系统可以避免蒸发器和蒸发器的两相流流体供应,从而降低IOoC温差。降低蒸发器中制冷剂的流动阻力。因此,产品的质量是改善。