摘要

In this paper,we discussed the principle of thermal pressure ventilation,tested the ventilation wall in hot and humid region and obtained the hourly temperature on the outer wall surface and the calcium silicate board surface.The results showed that,on sunny days,plug-calcium silicate board surface temperature can be up t0 37 0C,while the exterior wall surface temperature can be up t0 31 0C,the surface temperature difference between the two walls is about 60C.But on cloudy day,the difference is about 2.3 0C.And during the night,it is about l.5 0C.Lower temperatures are found for the plug-calcium silicate board surface compared with exterior wall surface temperature.The delay and attenuation effect on outdoor temperature wave by ventilation wall is conspicuous.
机译:本文讨论了热压通风的原理,测试了湿热地区的通风壁,并获得了外壁表面和硅酸钙板表面的每小时温度。结果表明,在晴天,硅酸钙板的表面温度最高可以达到t0 37 0C,而外墙的表面温度最高可以达到t0 31 0C,两壁之间的表面温度差约为60C。但是在阴天,温度差约为2.3 0C。在夜间,温度约为1.50°C。与外壁表面温度相比,插塞式硅酸钙板表面温度更低。通风墙对室外温度波的延迟和衰减影响非常明显。