This paper builds the numerical model of seawater desalination reactor passive engineered safety features integrated simulation test facility, and then analyzes the impact of the initial accumulator tank water level to the residual heat removal and the establishment of natural circulation in the emergency residual heat removal test. The results coincide with the experimental results well, which proves that RELAP5 code had the calculation and simulation capabilities to integrated simulation test.
机译:本文建立了海水淡化反应堆被动工程安全特性综合仿真试验装置的数值模型,然后在应急余热试验中分析了初始储罐水位对余热的影响以及自然循环的建立。结果与实验结果吻合良好,证明RELAP5代码具有集成仿真测试的计算和仿真能力。