Heat exchanger effectiveness of more than 90% is required for a J-T refrigerator to function when nitrogen is used as the refrigerant and over 95% when mixtures are used as the refrigerant. Coiled wire finned heat exchangers with effectiveness greater than 97% have been built and tested in our laboratory for use in J-T refrigerators operating with mixtures. Experiments have been conducted on prototype heat exchanger with a nitrogen-hydrocarbon mixture and temperature of the shell measured at some locations. The measured temperatures are compared with some single and two-phase heat transfer coefficient estimation methods available in the literature.
机译:J-T冰箱在使用氮气作为制冷剂时要发挥90%以上的换热效率,而在将混合物用作制冷剂时要达到95%以上。效率超过97%的盘绕翅片式换热器已经在我们的实验室中进行了建造和测试,可用于使用混合物的J-T冰箱。已经在原型热交换器上用氮-烃混合物进行了实验,并在某些位置测量了壳体的温度。将测得的温度与文献中提供的一些单相和两相传热系数估算方法进行了比较。