首页> 外文会议>International Institute of Refrigeration;IIR International congress of refrigeration;Ministry of Economy, Trade and Industry;Ministry of Agriculture, Forestry and Fisheries >STUDY ON THE USE OF EJECTORS FOR CAPACITY MODULATION AND PERFORMANCE IMPROVEMENT IN CO_2 COMMERCIAL REFRIGERATION SYSTEMS
【24h】

STUDY ON THE USE OF EJECTORS FOR CAPACITY MODULATION AND PERFORMANCE IMPROVEMENT IN CO_2 COMMERCIAL REFRIGERATION SYSTEMS

机译:射流器在CO_2商业制冷系统中进行容量调节和性能改善的研究

获取原文
获取原文并翻译 | 示例

摘要

Expansion work recovery by means of a two-phase ejector is an attractive option for improving the efficiency of CO_2 commercial refrigeration systems. However, the use of ejectors in a system subject to varying ambient conditions and capacity requirements presents a significant challenge, as ejectors have been seen to offer poor performance at off-design conditions. In order for ejector systems to be a realistic option for efficiency improvement, they must be able to operate efficiently at off-design and reduced capacity conditions. In this paper, existing CO_2 ejector data from the open literature is analyzed in order to see the impact on ejector component and system performance for operating an ejector cycle at off-design conditions, and different methods for addressing the issue of off-design and reduced capacity operation of ejector cycles are discussed. A theoretical model is used to investigate the performance of different CO_2 commercial refrigeration cycle configurations with two-phase ejectors.
机译:通过两相喷射器进行膨胀功回收是提高CO_2商业制冷系统效率的有吸引力的选择。然而,由于已经发现喷射器在非设计条件下的性能较差,因此在环境条件和容量要求不断变化的系统中使用喷射器提出了巨大的挑战。为了使喷射器系统成为提高效率的现实选择,它们必须能够在非设计和容量降低的情况下高效运行。在本文中,分析了来自公开文献的现有CO_2喷射器数据,以了解在非设计条件下操作喷射器循环对喷射器组件和系统性能的影响,以及解决非设计和减少排放问题的不同方法。讨论了喷射器循环的容量操作。理论模型用于研究带有两相喷射器的不同CO_2商业制冷循环配置的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号