首页> 外文会议>2018 2nd International Conference on Power, Energy and Environment: Towards Smart Technology >The Torque Simulation of Synchronous Generator Under Loaded Condition for Different Types of Electrical Disturbances
【24h】

The Torque Simulation of Synchronous Generator Under Loaded Condition for Different Types of Electrical Disturbances

机译:同步发电机在负载条件下不同类型电干扰的转矩仿真

获取原文
获取原文并翻译 | 示例

摘要

In this paper, the torque developed in the synchronous generator under the loaded condition is numerically simulated for various types of electrical faults. The dq0 approach is used to model synchronous generator connected to an infinite bus. The Adams fourth order predictor-corrector method with starter as fourth order Runge-Kutta method is used to numerically simulate the torque developed by the synchronous generator connected to load using MATLAB. The numerical results revealed that electromagnetic torque is most severe in synchronization fault followed by three phase fault, line to ground fault and line to line fault.
机译:本文针对各种电气故障,对负载条件下同步发电机产生的转矩进行了数值模拟。 dq0方法用于对连接到无限总线的同步发电机进行建模。以起动机为四阶Runge-Kutta方法的Adams四阶预测器-校正器方法用于数值模拟由使用MATLAB的负载连接的同步发电机产生的转矩。数值结果表明,电磁转矩在同步故障中最严重,其次是三相故障,线对地故障和线对线故障。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号